The initial configuration worksheet for the example topology is shown in the preview section.
SFSS configuration item | Value |
Hostname (cannot contain ".") | sfss |
Default Username | admin |
Default Password | admin |
Management Interface IP | 172.18.11.57 |
Management Mask/Prefix | 255.255.255.0/24 |
Management Gateway | 172.18.11.254 |
Associated CDC Instances | 1, 2 |
Storage interface MTU | 9000 |
IPv4 Internal Network | 172.16.0.0/16 |
IPv6 Internal Network | fe01::/64 |
NTP Server | 172.18.11.50 |
CDC instance ID configuration item | CDC 1 | CDC 2 |
SFSS FQDN / IP | sfss.dell.lab | sfss.dell.lab |
Storage interface IP | 172.18.21.250 | 172.18.22.250 |
Interface | ens192 | ens224 |
Storage subnet mask/prefix length | 255.255.255.0/24 | 255.255.255.0/24 |
Storage subnet default gateway | None (L2 topology only) | None (L3 topology only) |
Associated storage VLAN ID | 1821 | 1822 |
Zone Group Name | ZG-NVMe-SAN-A | ZG-NVMe-SAN-B |
Zone Name | Z-NVMe-SAN-A | Z-NVMe-SAN-B |
vCenter configuration item | Value |
vCenter FQDN / IP | vcenter.dell.lab / 172.18.11.62 |
Data Center | DC - NVMe/TCP |
SFSS's Host Cluster name | C01 - Management |
SFSS's Host Cluster vDS/vSwitch | C01-vDS-Management |
SFSS's Host Cluster Management Port Group | C01-Management |
Workload Management Port Group | C02-Management |
Workload Cluster name | C02 - Workload |
Workload Cluster LAN vDS | C02-vDS-Workload |
Workload Cluster NVMe/TCP vDS | C02-vDS-NVMeTCP |
NVMe/TCP Datastore name | PowerStore-NVMeTCP-DS |
ESXi host or cluster configuration item | SAN A | SAN B |
SFSS VM storage Port Group | C01-NVMeTCP-SAN-A-SFSS | C01-NVMeTCP-SAN-B-SFSS |
SFSS VM storage Port Group VLAN | 1821 | 1822 |
Workload Cluster storage Port Group | C01-NVMeTCP-SAN-A | C01-NVMeTCP-SAN-B |
Workload Cluster storage Port Group VLAN | 1821 | 1822 |
Workload Cluster storage network mask/prefix length | 255.255.255.0/24 | 255.255.255.0/24 |
Workload Cluster storage network gateway (L3 only) | None | None |
Workload Cluster storage network vmk interface IPs | 172.18.21.105-108 | 172.18.22.105-108 |
Workload Cluster Storage Software Adapter | vmhba64 | vmhba65 |
Port Number | 3 | 4 |
VM NIC name | vmnic2 | vmnic3 |
Linux configuration item | Value |
SFSS Host Management IP | 172.18.11.109 |
SFSS VM Management Bridge interface name | br0-mgmt |
SFSS VM SAN A Bridge interface name | br1-san-a |
SFSS VM SAN B Bridge interface name | br2-san-b |
Configuration item | Value |
PowerStore cluster FQDN/IP | Unisphere for PowerMax IP |
Volume Group names | VG-NVMe |
Volume Names | V-NVMe |
DDC Port Number | 8009 (Default) |
Configuration item | SAN A | SAN B |
Storage network name | NVMeTCP-SAN-A | NVMeTCP-SAN-B |
Storage network VLAN ID | 1821 | 1822 |
Storage network mask and prefix length | 255.255.255.0/24 | 255.255.255.0/24 |
Storage network gateway | None (L2 only) | None (L2 only) |
Storage network interface IPs | 172.18.21.191-192 | 172.18.22.191-192 |
Port Number | A2,B2 | A3,B3 |
PowerMax Configuration Item | Value |
Unisphere for PowerMax IP | 100.67.126.11 |
System ID | 120000603 |
Discovery Option | Auto Discovery of CDC IP Address |
DDC Port Number1 | 8009 |
PowerMax Storage Network Configuration Item | SAN A | SAN B |
Port | 4 | 4 |
Director | OR:1C | OR:2C |
Network ID | 1821 | 1822 |
VLAN ID | 1821 | 1822 |
TCP Port (I/O) | 4420 | 4420 |
Endpoint name | SAN A | SAN B |
IP address | 172.18.21.181 | 172.18.22.181 |
Prefix length | 24 | 24 |
MTU | Jumbo | Jumbo |