The following table shows the switch interface configuration for a pair of dedicated, air-gapped SAN PowerSwitch systems running SmartFabric OS10 in full switch mode. Notice that there are no uplinks to the rest of the network, and there are no connections between the switches.
SAN switch 1 - SAN A | SAN switch 2 - SAN B |
|
|
The following table shows the switch interface configuration for a pair of dedicated, air-gapped SAN PowerSwitch systems running Enterprise SONiC Distribution by Dell Technologies. For more information see Unleash the Power of NVMe over TCP with Enterprise SONiC by Dell Technologies.
SAN switch 1 - SAN A | SAN switch 2 - SAN B |
|
|
For IPv6 solutions, MLD snooping must be disabled to facilitate automated discovery of endpoints. Consult your switch vendor's documentation to determine if MLD snooping is enabled by default and requires configuration to disable.
SAN A | SAN B |
OS10(config)# interface vlan1821 OS10(conf-if-vl-1821)# no ipv6 mld snooping In OS10, MLD snooping can be disabled globally OS10(config)# no ipv6 mld snooping enable | OS10(config)# interface vlan1822 OS10(conf-if-vl-1822)# no ipv6 mld snooping In OS10, MLD snooping can be disabled globally OS10(config)# no ipv6 mld snooping enable |