Perform the following steps to edit uplinks on a SmartFabric:
- Open the OME-M console.
- From the navigation menu, click Devices > Fabric.
- Select the fabric.
- Select the Uplink to edit and click Edit. Note: In this example, Uplink1 is selected.
- In the Edit Uplink dialog box, modify the Name and Description as necessary. Note: The uplink type cannot be modified once the fabric is created. If the uplink type must be changed after the fabric is created, delete the uplink and create a new uplink with the wanted uplink type.
Note: The Include in Uplink Failure Detection Group box under Uplink Type will only be seen on OME-M 1.20.00 and later.
- Click Next.
- Edit the Uplink ports on the MX switches that connect to the upstream switches. In this example, ports 41 and 42 that are on the MX9116n switches, connect to upstream switches, and are displayed. Note: Carefully modify the uplink ports on both MX switches. Select the IOM to display the respective uplink switch ports.
- If necessary, modify the tagged and untagged VLANs. Note: If you have changed OME-M to use a VLAN other than the default, make sure that you do not add that VLAN to an uplink.
Note: An FCoE uplink from the MX5108n or MX9116n must contain only a single port interface on an MX IOM to the existing FCoE switch such as the Dell PowerSwitch S4148U shown in the diagram above.
- Click Finish.