This deployment example uses the teaming policies for ECMP uplinks shown in the following table.
Table 9. Uplink teaming policies
Name
Teaming policy
Active uplinks
uplink-1-teaming-policy
Failover Order
uplink-1
uplink-2-teaming-policy
Failover Order
uplink-2
To apply the teaming policies, edit the edge-overlay-profile as follows.
On the Uplink Profiles page, check the box next to edge-overlay-profile and click EDIT.
In the Edit Uplink Profile window, under Teamings, click +ADD. A new row is added below [Default Teaming].
In the new row, add the first teaming policy from the previous table.
Click +ADD. A new row is added below [Default Teaming].
In the new row, add the second teaming policy from the previous table.
After the two policies are added, the Teamings section of the screen appears as follows:
Click SAVE.
Include the new edge-overlay-profile teaming policies in the edge-uplink-tz transport zone as follows:
In the NSX Manager web UI, select System > Fabric > Transport Zones.
Select the edge-uplink-tz transport zone and click EDIT.
In the Edit Transport Zone window, next to Uplink Teaming Policy Names, enter uplink-1-teaming-policy and uplink-2-teaming-policy as shown in the following figure: