The following table shows the networks used by VxRail nodes in the workload domain for this deployment example.
VLAN ID | Description | Name | Network | Gateway |
4091 | SFS Client Management/ VxRail cluster build | Client_ Management | N/A | None |
3939 | VxRail node discovery | Client_Control | IPv6 multicast | None |
1821 | External Management | w01-ext-mgmt | 172.18.21.0/24 | 172.18.21.254 |
1822 | vMotion | w01-vmotion | 172.18.22.0/24 | None |
1823 | vSAN | w01-vsan | 172.18.23.0/24 | None |
2600 | NSX host overlay | w01-host-overlay | 172.26.101.0/24 (Rack 1) 172.26.102.0/24 (Rack 2*) 172.26.10n.0/24 (Rack n*) | 172.26.101.254 (Rack 1) 172.26.102.254 (Rack 2*) 172.26.10n.254 (Rack n*) |
2721 | NSX edge uplink 1 | w01-edge-uplink1 | 172.27.21.0/24 | None |
2722 | NSX edge uplink 2 | w01-edge-uplink2 | 172.27.22.0/24 | None |
2723 | NSX edge overlay | w01-edge-overlay | 172.27.23.0/24 | 172.27.23.254 |
Rack 2 and higher (represented by Rack “n”) only apply to multirack topologies. Configure one unique w01 NSX host overlay network and gateway for each rack in the SmartFabric.
Note: SFS automatically creates VLANs 4091 and 3939. The remaining VLAN IDs and their network IP addresses shown in the table above are user-defined and are examples only. In SmartFabric mode, VLANs 1 through 3999, excluding 3939, are available for use.