Several Dell PowerSwitch options are available, and switch options depend largely on intended use and scale. The suggested top-of-rack (ToR) switch options are listed below as a guideline. Some customers may already have a plan in place, or they may have an existing network infrastructure. The switch model recommendations below are neither mandatory nor prescriptive.
It is recommended to separate management and gateways onto one set of switches and data traffic to separate switch fabrics. For each type of traffic, the following Dell PowerSwitch options can be used:
For Management and Dell Edge Gateway connections:
- Dell PowerSwitch S4148T
For data path traffic, see the following options:
- Dell PowerSwitch S5248F-ON
- Dell PowerSwitch S5232F-ON
For technical specifications, see the following tables.
Specification | S4148T-ON |
Ports | 48x 10 GbT 2x QSFP+ 4x QSFP28 |
Max 10 GbE density | 72 (48 10 GbT and 24 using QSFP28 breakout) |
Max 25 GbE density | 16 using QSFP28 breakout |
Max 40 GbE density | 6 |
Max 50 GbE density | 8 |
Max 100 GbE density | 4 |
Switching capacity | 1.76 Tbps |
Throughput | 1320 Mpps |
Latency | <2.3 µs |
1588v2 PTP timing | supported |
Max power consumption | 440 W |
Typical operating power | 320 W |
Number of fan trays | 4 |
Fans per fan tray | 2 |
Weight | 22.37 lbs (10.15 kg) |
Max thermal output | 1,500 BTU/h |
Specification | S5248F-ON | S5232F-ON |
Ports | 48x SFP28 2x QSFP28-DD 4x QSFP28 | 32x QSFP28 2x SFP+ |
Max 10 GbE density | 48 (SFP28) 16 (QSFP28-DD breakout) 16 (QSFP28 breakout) | 124 (QSFP28 breakout) 2 (SFP+) |
Max 25 GbE density | 48 (SFP28) 16 (QSFP28-DD breakout) 16 (QSFP28 breakout) | 124 (QSFP28 breakout) |
Max 40 GbE density | 8 (QSFP28) | 32 (QSFP28) |
Max 50 GbE density | 16 (QSFP28 breakout) | 64 (QSFP28 breakout) |
Max 100 GbE density | 8 (QSFP28) | 32 (QSFP28) |
Switching capacity | 3.2 Tbps (6.4 Tbps full duplex) | 3.2 Tbps (6.4 Tbps full duplex) |
Throughput | 2.4 Bpps (4.8 Bpps full duplex) | 2.4 Bpps (4.8 Bpps full duplex) |
Latency (nano sec) | 850 | 877 |
1588v2 PTP timing | supported | supported |
CPU memory | 16 GB | 16 GB |
SSD | 64 GB | 64 GB |
Packet buffer | 32 MB | 32 MB |
Typical power | 647 W | 635 W |
Maximum current | 5.8 A @ 110 VAC / 2.9 A @ 220 VAC | 5.8 A @ 110 VAC / 2.9 A @ 220 VAC |
Fan modules | 4 | 4 |
Form factor | 1U | 1U |
Dimensions | 17.1" W x 18.1" D x1.7" H 43.4 W x 46.0 D x 4.4 H (cm) | 17.1" W x 18.1" D x 1.7" H 43.4 W x 46.0 D x 4.4 H (cm) |
Weight | 9.7 kg (21.4 lb) | 9.8 kg (21.6 lb) |
Max thermal output | 2208 BTU/h | 2167 BTU/h |