A cluster of four VxRail E560 nodes was used to validate the VI-WLD in this guide. The nodes were each configured using the information that is provided in Table 19. The values in Table 19 can also be found in the VxRail Support Matrix.
Table 19. VxRail node components
Qty per node | Item | Firmware version |
2 | Intel Xeon Gold 6136 CPU @ 3.00GHz, 12 cores | - |
12 | 16GB DDR4 DIMMs (192GB total) | - |
2 | 800GB SAS SSD | - |
8 | 1.2TB SAS HDD | EF03 |
1 | Dell HBA330 Storage Controller | 15.17.09.06 |
1 | Boot Optimized Storage Solution (BOSS) Controller w/ 2x240GB SATA SSDs | 2.5.13.3016 |
1 | Broadcom 57414 NDC – 2x25GbE SFP28 ports | 21.40.22.21 |
1 | Broadcom 57414 NIC – 2x25GbE SFP29 ports | 21.40.22.21 |
- | BIOS | 2.1.8 |
- | iDRAC with Lifecycle Controller | 3.32.32.32 |