Home > Integrated Products > VxRail > Guides > Architecture Guide—VMware Cloud Foundation on VxRail: VCF 4.5 on VxRail 7.0 > NSX vDS
Starting with VCF 4.0.1, you can fully separate system traffic and NSX-T traffic for both the management WLD and VI WLD using a second vDS dedicated for NSX traffic. For the management WLD, additional optional inputs are required. Cloud Builder creates and configures the second vDS during VCF bring-up. For the VI WLD, a script available in Developer Center in the SDDC Manager must be used to add a VxRail cluster with a second vDS to the VI WLD. The additional input that is needed for the vDS must be provided to the script during execution.
Note: VCF orders the vmnic to uplink mapping on the vDS lexicographically (lowest to highest), even if the order in the input spreadsheet for the Mgmt WLD or the input to the script in the VI WLD are not ordered lexicographically.