VCF requires the following additional VLANs created and configured on the TOR switches connecting to VxRail nodes in the management WLD VxRail cluster.
Note: From VCF 4.3, the Edge cluster for the management WLD is deployed as a Day-2 operation from the SDDC Manager. It is no longer deployed by Cloud Builder during the initial management WLD deployment.
Network traffic | Sample VLAN |
NSX-T Host TEP | 103 |
NSX-T Edge TEP | 104 |
Edge Uplink01 | 105 |
Edge Uplink02 | 106 |
VCF requires the following additional VLANs created and configured on the TOR switches before deploying a VI WLD:
Workload domain type | Network traffic | Sample VLAN |
VI WLD | NSX-T Host TEP | 203 |
VI WLD (Edge deployment only) | NSX-T Edge TEP | 204 |
VI WLD (Edge deployment only) | Edge Uplink01 | 205 |
VI WLD (Edge deployment only) | Edge Uplink02 | 206 |