Verify the following if server or FEM discovery does not happen:
- Verify that the compute sled is properly seated in the compute slot in the MX7000 chassis.
- Verify that at least one compute sled in the chassis is powered on.
- If the connected FSE port does not show a link up, toggle the auto negotiation settings for that port.
- Confirm that all of the firmware on the compute sleds is up to date and aligned with the installed MX baseline.
- If a QLogic/Marvell 41262 or 41232 adapter is used in the compute sled, the link speed setting on the adapter should be set to SmartAN.
- Check the Topology LLDP settings. You can verify the settings by selecting iDRAC Settings > Connectivity from the iDRAC UI that is on the compute sled. Check that this setting is set to Enabled as shown in the following figure.