- Connect to the MX computer sled server's iDRAC in a web browser and log in.
- Select System, then click Network Devices.
- Click the CNA. In this example, NIC Mezzanine 1A is used. Under Ports and Partitioned Ports, the FCoE partition for each port is displayed as shown in the following figure.
- The first FCoE partition is Port 1, Partition 2. Click the (+) icon to view the MAC Addresses as shown in the following figure.
- Record the MAC Address and WWPN. Note: A convenient method is to copy and paste these values into a text file.
- Repeat steps 4 and 5 for the FCoE partition on port 2.
- Repeat the steps in this section for the remaining MX740c servers.
The FCoE WWPNs and MAC addresses used in this deployment example are shown in the following table:
Table 44. Server CNA FCoE port WWPNs and MACs Server Port WWPN MAC MX740c-1 1 20:01:F4:E9:D4:0C:24:F218:66:DA:71:50:AD 18:66:DA:71:50:ACF4:E9:D4:0C:24:F2 MX740c-2 2 20:01:F4:E9:D4:0C:24:F320:01:18:66:DA:71:50:AF F4:E9:D4:0C:24:F318:66:DA:71:50:AE MX740c-2 1 20:01:34:80:0D:86:80:6218:66:DA:77:D0:C3 34:80:0D:86:80:6218:66:DA:77:D0:C2 MX740c-2 2 20:01:34:80:0D:86:80:6320:01:18:66:DA:77:D0:C5 34:80:0D:86:80:618:66:DA:77:D0:C34