Once the SmartFabric is created using OME-M, create port channel 1 on the S5232F-ON leaf switches to connect to the MX9116n FSEs. Also create the VLTi domain for connection between S5232-ON leaf switches.
Note: Ports 1/1/1 and 1/1/3 are added to the port channel in the next section.
Use the switchport mode trunk command to enable the port channel to carry traffic for multiple VLANs, and allow all VLANs on the port channel.
Use the 100 GbE interfaces for the port channel in the VLTi. VLTi ports are 1/1/29 and 1/1/31 for both switches in this example. Add each interface to the port channel as LACP active members using the channel-group 1 mode active command.
Table 4.
Switch Interconnect and VLTi Configuration Commands
interface port-channel 1
description To_MX_Chassis
no shutdown
switchport access vlan 1
switchport mode trunk
switchport trunk allowed vlan 1611-1617,1649
mtu 9216
vlt-port-channel 1
interface ethernet1/1/29
description To_Leaf_1B
no shutdown
no switchport
mtu 9216
interface ethernet1/1/31
description To_Leaf_1B
no shutdown
no switchport
mtu 9216
vlt-domain 1
backup destination 100.67.YY.YY
discovery-interface ethernet 1/1/29, 1/1/31
peer-routing |
interface port-channel 1
description To_MX_Chassis
no shutdown
switchport access vlan 1
switchport mode trunk
switchport trunk allowed vlan 1611-1617,1649
mtu 9216
vlt-port-channel 1
interface ethernet1/1/29
description To_Leaf_1A
no shutdown
no switchport
mtu 9216
interface ethernet1/1/31
description To_Leaf_1A
no shutdown
no switchport
mtu 9216
vlt-domain 1
backup destination 100.67.XX.XX
discovery-interface ethernet 1/1/29, 1/1/31
peer-routing |