We conducted validation tests to determine how FLIR Latitude works with Unity storage arrays.
Our testing found the best bandwidth to be 27 MB/s on a VM Archiver. The tests included an overall read bandwidth of 20 percent. Maximum per Archiver bandwidth may vary based on the configuration of the Archiver server used. All testing was conducted using the iSCSI protocol.
Test results are based on a conservative model to ensure that the constant-bandwidth video traffic is unaffected during a single storage pool (SP) maintenance cycle, disk rebuild, or similar performance-intensive event.
All test results are based on multiple servers writing to a Unity storage array.
Extrapolated based on Dell EMC Safety & Security Lab test results.Array | Latitude | RAID | Disks | No. of Archivers | Bandwidth (MB/s) | Maximum (RAW) | |
Per Archiver | Array iSCSI | ||||||
Unity300 | 8.0.X.61XX | 6 | 64 | 8 | 27 | 225 | 2.34 PB |
104 | 12 | 27 | 338 | ||||
Unity400 1 | 8.0.X.61XX | 6 | 64 | 12 | 27 | 270 | 3.9 PB |
104 | 18 | 27 | 405 | ||||
240 | 40 | 27 | 901 | ||||
Unity500 | 8.0.X.61XX | 6 | 64 | 12 | 27 | 324 | 7.8 PB |
104 | 18 | 27 | 486 | ||||
240 1 | 40 | 27 | 1080 | ||||
500 1 | 84 | 27 | 2268 | ||||
Unity600 1 | 8.0.X.61XX | 6 | 64 | 12 | 27 | 372 | 9.7 PB |
104 | 18 | 27 | 558 | ||||
240 | 40 | 27 | 1242 | ||||
500 | 84 | 27 | 2608 |