Home > Integrated Products > VxRail > Guides > Architecture Guide—VMware Cloud Foundation 5.1 on VxRail > Additional VCF NSX networks
VCF requires the following additional VLANs created and configured on the TOR switches connecting to VxRail nodes in the management WLD VxRail cluster.
Note: The Edge cluster for the management WLD is deployed as a Day-2 operation from the SDDC Manager.
Network traffic | Sample VLAN |
NSX Host TEP | 103 |
NSX Edge TEP | 104 (Can be the same as Host TEP) |
Edge Uplink01 | 105 |
Edge Uplink02 | 106 |
VCF requires the following additional VLANs created and configured on the TOR switches before deploying a VI WLD.
Workload domain type | Network traffic | Sample VLAN |
VI WLD | NSX Host TEP | 203 |
VI WLD (Edge deployment only) | NSX Edge TEP | 204(Can be same as Host) |
VI WLD (Edge deployment only) | Edge Uplink01 | 205 |
VI WLD (Edge deployment only) | Edge Uplink02 | 206 |
Note: The Edge deployment is a Day 2 operation that can be achieved using either the Edge automation or a manual deployment after the VI WLD has been deployed.