Home > Networking Solutions > Converged and Hyperconverged Solutions > VxRail Networking Solutions > Guides > Dell EMC Networking SmartFabric Services Deployment with VxRail 7.0 > Connect to the SmartFabric GUI
Note: After reloading the switches, it takes about 2 minutes after the login prompt displays at the switch CLI for SFS to come up and for the GUI to be fully functional.
Note: The SFS GUI supports Chrome, Firefox, and Edge browsers. Languages other than English are not currently supported.
All GUI configuration is done on the SFS master switch. If you connect to an SFS switch that is not the master, a link to the master is provided. This is outlined in red in Figure 13.
Figure 13. Connected to switch that is not the master
Note: The IPv4 address of the SFS master may also be determined by running show smartfabric cluster from the CLI of any switch in the SmartFabric. The master is always a leaf switch, never a spine. Only one leaf switch in the SmartFabric will have ROLE set to MASTER. The remaining leafs will have ROLE set to BACKUP.
When connected to the SFS master switch, the GUI appears, as shown in Figure 14.
Figure 14. Connected to SFS master switch
Figure 15. Node details
Figure 16. VLTi link details