chapters
PowerEdge MX Scalable Fabric Architecture
Overview of SmartFabric Services for PowerEdge MX
-
1Overview of SmartFabric Services for PowerEdge MX
-
2Functional overview
-
3OS10 operating mode differences
-
4CLI commands available in SmartFabric mode
-
5IOM slot placement in SmartFabric mode
-
6Switch-to-switch (VLTi) cabling
-
7Configuring port speed and breakout
-
8VLAN scaling guidelines
-
9Maximum Transmission Unit behavior
-
10Layer 2 Multicast, IGMP, and MLD snooping
-
11Upstream network requirements
-
12Other restrictions and guidelines
-
13Ethernet – No Spanning Tree uplink
-
14Spanning Tree Protocol - legacy Ethernet uplink
-
15Networks and automated QoS
-
16Server templates, profiles, virtual identities, networks, and deployment
-
17VMware vCenter integration - OpenManage Network Integration
-
18OpenManage Integration for VMware vCenter
SmartFabric Creation
-
1SmartFabric Creation
-
2Steps to create a SmartFabric
-
3Physically cable PowerEdge MX chassis and upstream switches
-
4Define VLANs
-
5Create the SmartFabric
-
6Optional steps
-
7Create Ethernet – No Spanning Tree uplink
-
8Ethernet – No Spanning Tree upstream switch configuration
-
9Optional - Configure Fibre Channel
-
10Enable support for larger VLAN counts
-
11Uplink failure detection
-
12Configuring the upstream switch and connecting uplink cables
SmartFabric Operations
-
1SmartFabric Operations
-
2Viewing SmartFabric health and status
-
3Edit a SmartFabric
-
4Edit uplinks
-
5Edit VLANs
-
6Delete SmartFabric
-
7Connect non-MX Ethernet devices to a SmartFabric
-
8Expanding from a single-chassis to dual-chassis configuration
-
9SmartFabric mode IOM replacement process
-
10MXG610 Fibre Channel switch module replacement process
-
11Chassis Backup and Restore
General Troubleshooting
-
1General Troubleshooting
-
2View or extract logs using OME-M
-
3Troubleshooting MCM topology errors
-
4Troubleshooting VLT and vPC configuration on upstream switches
-
5Troubleshooting FEM and compute sled discovery
-
6Troubleshooting FC and FCoE
-
7Rebalancing FC and FCoE sessions
-
8Common CLI troubleshooting commands for Full Switch and SmartFabric modes
SmartFabric Troubleshooting
-
1SmartFabric Troubleshooting
-
2Troubleshooting SmartFabric issues
-
3Troubleshoot port group breakout errors
-
4Troubleshooting VLTi between switches
-
5Troubleshooting uplink errors
-
6Troubleshooting legacy Ethernet uplink with STP
-
7Troubleshooting common issues
-
8SmartFabric Services troubleshooting commands
Configuration Scenarios
-
1Configuration Scenarios
-
2Scenario 1: SmartFabric deployment with S5232F-ON upstream switches with Ethernet - No Spanning Tree uplink
-
3Scenario 2: SmartFabric connected to Cisco Nexus 3232C switches with Ethernet - No Spanning Tree uplink
-
4Scenario 3: SmartFabric deployment with S5232F-ON upstream switches with legacy Ethernet uplink
-
5Scenario 4: SmartFabric connected to Cisco Nexus 3232C switches with legacy Ethernet uplink
-
6Scenario 5: Connect MX9116n FSE to Fibre Channel storage - NPIV Proxy Gateway mode
-
7Scenario 6: Connect MX9116n FSE to Fibre Channel storage - FC Direct Attach
-
8Scenario 7: Connect MX5108n to Fibre Channel storage - FSB
-
9Scenario 8: Configure boot from SAN
PowerEdge MX 100 GbE solution with external Fabric Switching Engine
-
1PowerEdge MX 100 GbE solution with external Fabric Switching Engine
-
2PowerEdge MX models and components for 100 GbE
-
3PowerEdge Scalable Fabric Architecture
-
4MX8116n management
-
5Z9432F-ON management
-
6MX8116n FEM port mapping on the Z9432F-ON
-
7100 GbE solution configuration examples
-
8100 GbE solution configuration validation
-
9100 GbE combined deployment with legacy IOMs
-
10100 GbE deployment with rack servers
Additional Tasks
Dell PowerSwitch S4148U-ON Configuration in Scenario 7
Hardware and Version Information
PowerEdge MX Scalable Fabric Architecture
Overview of SmartFabric Services for PowerEdge MX
-
1Overview of SmartFabric Services for PowerEdge MX
-
2Functional overview
-
3OS10 operating mode differences
-
4CLI commands available in SmartFabric mode
-
5IOM slot placement in SmartFabric mode
-
6Switch-to-switch (VLTi) cabling
-
7Configuring port speed and breakout
-
8VLAN scaling guidelines
-
9Maximum Transmission Unit behavior
-
10Layer 2 Multicast, IGMP, and MLD snooping
-
11Upstream network requirements
-
12Other restrictions and guidelines
-
13Ethernet – No Spanning Tree uplink
-
14Spanning Tree Protocol - legacy Ethernet uplink
-
15Networks and automated QoS
-
16Server templates, profiles, virtual identities, networks, and deployment
-
17VMware vCenter integration - OpenManage Network Integration
-
18OpenManage Integration for VMware vCenter
SmartFabric Creation
-
1SmartFabric Creation
-
2Steps to create a SmartFabric
-
3Physically cable PowerEdge MX chassis and upstream switches
-
4Define VLANs
-
5Create the SmartFabric
-
6Optional steps
-
7Create Ethernet – No Spanning Tree uplink
-
8Ethernet – No Spanning Tree upstream switch configuration
-
9Optional - Configure Fibre Channel
-
10Enable support for larger VLAN counts
-
11Uplink failure detection
-
12Configuring the upstream switch and connecting uplink cables
SmartFabric Operations
-
1SmartFabric Operations
-
2Viewing SmartFabric health and status
-
3Edit a SmartFabric
-
4Edit uplinks
-
5Edit VLANs
-
6Delete SmartFabric
-
7Connect non-MX Ethernet devices to a SmartFabric
-
8Expanding from a single-chassis to dual-chassis configuration
-
9SmartFabric mode IOM replacement process
-
10MXG610 Fibre Channel switch module replacement process
-
11Chassis Backup and Restore
General Troubleshooting
-
1General Troubleshooting
-
2View or extract logs using OME-M
-
3Troubleshooting MCM topology errors
-
4Troubleshooting VLT and vPC configuration on upstream switches
-
5Troubleshooting FEM and compute sled discovery
-
6Troubleshooting FC and FCoE
-
7Rebalancing FC and FCoE sessions
-
8Common CLI troubleshooting commands for Full Switch and SmartFabric modes
SmartFabric Troubleshooting
-
1SmartFabric Troubleshooting
-
2Troubleshooting SmartFabric issues
-
3Troubleshoot port group breakout errors
-
4Troubleshooting VLTi between switches
-
5Troubleshooting uplink errors
-
6Troubleshooting legacy Ethernet uplink with STP
-
7Troubleshooting common issues
-
8SmartFabric Services troubleshooting commands
Configuration Scenarios
-
1Configuration Scenarios
-
2Scenario 1: SmartFabric deployment with S5232F-ON upstream switches with Ethernet - No Spanning Tree uplink
-
3Scenario 2: SmartFabric connected to Cisco Nexus 3232C switches with Ethernet - No Spanning Tree uplink
-
4Scenario 3: SmartFabric deployment with S5232F-ON upstream switches with legacy Ethernet uplink
-
5Scenario 4: SmartFabric connected to Cisco Nexus 3232C switches with legacy Ethernet uplink
-
6Scenario 5: Connect MX9116n FSE to Fibre Channel storage - NPIV Proxy Gateway mode
-
7Scenario 6: Connect MX9116n FSE to Fibre Channel storage - FC Direct Attach
-
8Scenario 7: Connect MX5108n to Fibre Channel storage - FSB
-
9Scenario 8: Configure boot from SAN
PowerEdge MX 100 GbE solution with external Fabric Switching Engine
-
1PowerEdge MX 100 GbE solution with external Fabric Switching Engine
-
2PowerEdge MX models and components for 100 GbE
-
3PowerEdge Scalable Fabric Architecture
-
4MX8116n management
-
5Z9432F-ON management
-
6MX8116n FEM port mapping on the Z9432F-ON
-
7100 GbE solution configuration examples
-
8100 GbE solution configuration validation
-
9100 GbE combined deployment with legacy IOMs
-
10100 GbE deployment with rack servers