Home > Servers > Systems Management > White Papers > Server Configuration Profiles: Reference Guide > Selective export
By default, SCP Export generates a template that includes most configurable devices on the host system, including iDRAC, Lifecycle Controller, System, EventFilters, BIOS, NIC, Fibre Channel, InfiniBand, and RAID/storage devices. All available interfaces offer the option to selectively export only requested devices or device types.
Example:
racadm get ‐t xml ‐f export.xml ‐u username ‐p password ‐l //ip/share/ ‐c iDRAC,NIC.Integrated.1‐1‐1
racadm provides the -c option for selective export. In the preceding example, export.xml will be exported to a network share and will contain the iDRAC.Embedded.1 component and the NIC.Integrated.1-1-1 component.
Most interfaces allow for both full FQDD or a shorthand version to export all components of a given type. The shorthand NIC would export NIC.Integrated.1-1-1, NIC.Integrated.2-1-1, and so on, but full FQDD NIC.Integrated.1-1-1 would only provide the component for that specific device.
Note: Shorthand values can be used for SCP Export or SCP Import.
Shorthand | FQDD |
AHCI | AHCI.* |
BIOS | BIOS.Setup.1-1 |
Disk | Disk.* |
EventFilters | EventFilters.*.1 |
FC | FC.* |
iDRAC | iDRAC.Embedded.1 |
InfiniBand | InfiniBand.* |
LifecycleController | LifecycleController.Embedded.1 |
NIC | NIC.* |
NonRAID | NonRAID.* |
PCIeExtender | PCIeExtender.* |
PCIeSSD | PCIeSSD.* |
RAID | *** Exports/Imports all storage devices *** |
SupportAssist | SupportAssist.Embedded.1 |
System | System.Embedded.1 |