Home > Servers > Systems Management > White Papers > Server Configuration Profiles: Reference Guide > Enabling SEKM on a PERC device with a locked RAID volume
Virtual disk creation in this workflow is similar to the steps described in Creating and initializing a virtual disk. The two key differences are the EncryptionMode and LockStatus attributes.
<Component FQDD="RAID.Slot.3‐1">
<Attribute Name="RAIDresetConfig">True</Attribute>
<Attribute Name="EncryptionMode">Secure Enterprise Key Manager</Attribute>
<Component FQDD="Disk.Virtual.0:RAID.Slot.3‐1">
<Attribute Name="RAIDaction">Create</Attribute>
<Attribute Name="LockStatus">Locked</Attribute>
<Attribute Name="BootVD">True</Attribute>
<Attribute Name="RAIDinitOperation">None</Attribute>
<Attribute Name="DiskCachePolicy">Disabled</Attribute>
<Attribute Name="RAIDdefaultWritePolicy">WriteBack</Attribute>
<Attribute Name="RAIDdefaultReadPolicy">ReadAhead</Attribute>
<Attribute Name="Name">SCP VD</Attribute>
<Attribute Name="Size">0</Attribute>
<Attribute Name="StripeSize">512</Attribute>
<Attribute Name="SpanDepth">1</Attribute>
<Attribute Name="SpanLength">2</Attribute>
<Attribute Name="RAIDTypes">RAID 1</Attribute>
<Attribute Name="IncludedPhysicalDiskID">Disk.Bay.0:Enclosure.Internal.0‐1:RAID.Slot.3‐ 1</Attribute>
<Attribute Name="IncludedPhysicalDiskID">Disk.Bay.1:Enclosure.Internal.0‐1:RAID.Slot.3‐ 1</Attribute>
</Component>
</Component>
To enable SEKM on the PERC device, change the EncryptionMode on your PERC device to Secure Enterprise Key Manager. The virtual disk on the device can be locked by updating LockStatus to Locked. The configuration results for the SCP Import operation reflect the new settings after job completion.
racadm>>lclog viewconfigresult ‐j JID_581203847849 SeqNumber = 6094
FQDD = RAID.Slot.3‐1
DisplayValue = PERC H740P Adapter Name = PERC H740P Adapter
Status = Success
DisplayValue = PERC H740P Adapter Name = PERC H740P Adapter
Status = Success DisplayValue = SCP VD Name = SCP VD NewValue = RAID 1
NewValue = Physical Disk 0:1:0 NewValue = Physical Disk 0:1:1
NewValue = Virtual Disk Size in Bytes : 899527213056 NewValue = Virtual Disk Stripe Size : 256 Kb NewValue = Physical Disks per Span : 2
NewValue = VirtualDisk Lock status: Locked
Status = Success DisplayValue = RAIDbootVD Name = RAIDbootVD OldValue = None
NewValue = Disk.Virtual.0:RAID.Slot.3‐1 Status = Success
SeqNumber = 6091 FQDD = RAID.Slot.3‐1
DisplayValue = PERC H740P Adapter Name = PERC H740P Adapter
Status = Success
DisplayValue = PERC H740P Adapter Name = PERC H740P Adapter
Status = Success
For more details about SEKM, see Enable OpenManage Secure Enterprise Key Manager (SEKM) on Dell PowerEdge Servers.