Home > Networking Solutions > Converged and Hyperconverged Solutions > VxRail Networking Solutions > Guides > VMware Cloud Foundation on VxRail Multirack Deployment Using BGP EVPN - Part 2 of 2 > Add the NSX-T edge nodes to the transport zones
After you deploy the NSX-T edge nodes and join them to the management plane, to connect the nodes to the workload domain. Next, add the nodes to the transport zones for uplink and overlay traffic and configure the N-VDS on each edge node. Table 16 shows the values that are used for both edge nodes.
Table 16. Edge node transport zone settings
Setting |
Value for sfo01wesg01 |
Value for sfo01esg02 |
Transport Zones |
sfo01-w-uplink01(VLAN) |
sfo01-w-uplink01(VLAN) |
sfo01-w-uplink02(VLAN) |
sfo01-w-uplink02(VLAN) |
|
sfo01-w-overlay(Overlay) |
sfo01-w-overlay(Overlay) |
Table 17 shows the Edge node N-VDS settings.
Table 17. Edge node N-VDS settings
Setting |
Value for sfo01wesg01 |
Value for sfo01esg02 |
Edge Switch Name |
sfo01-w-nvds01 |
sfo01-w-nvds01 |
Uplink Profile |
sfo01-w-overlay-profile |
sfo01-w-overlay-profile |
IP Assignment |
Use Static IP List |
Use Static IP List |
Static IP List |
172.16.49.21 |
172.16.49.22 |
Gateway |
172.16.49.253 |
172.16.49.253 |
Subnet Mask |
255.255.255.0 |
255.255.255.0 |
Virtual NICs |
fp-eth0 uplink-1 |
fp-eth0 uplink-1 |