Home > Storage > PowerStore > Storage Admin > Extending the Power of Dell Converged Infrastructure with Dell PowerStore AppsON > Configure AMP Central
There are two methods that can be used to discover and initially configure a PowerStore X cluster from a VM on AMP Central:
This section documents the configuration changes on AMP Central when the PowerStore X cluster is physically attached to VxBlock ToR switches or Vscale leaf switches.
Follow these steps to ensure successful discovery of the PowerStore X appliance(s) attached to a VxBlock 1000 System or to a Vscale Open FTC.
Note: Be sure to have configured the AMP Server ports on the VxBlock ToR switches, AMP Central Standalone ToR switches, or Vscale FTE leaf switches, according to the port configuration example in the Configure AMP Central server network switch ports section.
Set the IPv4 IP address to 169.254.0.5 with a netmask of 255.255.0.0 and no gateway address.
Take all the defaults. Do not add a VLAN ID.