Dell Technologies recommends that you follow the guidelines that are described in this section.
Dell Technologies recommends that you follow the guidelines that are described in this section.
Storage Spaces Direct uses RDMA for SMB (storage) traffic for improved performance. When SMB signing is enabled the network performance of SMB traffic is significantly reduced.
For more information, see Reduced networking performance after you enable SMB Encryption or SMB Signing in Windows Server 2016.
For performance optimization and reliability, update the hardware timeout configuration for the Spaces port.
The following PowerShell command updates the configuration in the Windows registry and induces a restart of the node at the end of the registry update. Perform this update on all Storage Spaces Direct nodes immediately after initial deployment. Update one node at a time and wait until each node rejoins the cluster.
Set-ItemProperty -Path HKLM:\SYSTEM\CurrentControlSet\Services\spaceport\Parameters -Name HwTimeout -Value 0x00002710 -Verbose
Restart-Computer -Force
Enabling jumbo frames specifically on the interfaces supporting the storage network improve read/write performance of the Azure Stack HCI cluster. An end-to-end configuration of jumbo frames is required to take advantage of this technology. Configure jumbo frame by using the MTU configuration value "9014" bytes for the storage work endpoints.
For information about configuring jumbo frames at the switch port level, see Sample Network Switch Configuration Files.