Table 4. PowerEdge server component details
Component |
Description |
|
Database server chassis |
R740xd with up to 24 x 2.5” HDD including max of 12 NVMe drives |
|
Processor |
2 x Intel Xeon Platinum 8280M 2.7GHz, 28c/56T, 10.4GT/s, Turbo |
|
DRAM |
- 384 GB [12 x 32 GB RDIMMs 2933 MT/s DR] - 768 GB [12 x 64 GB RDIMMs 2933 MT/s DR] - 1.5 TB [24 x 64 GB RDIMMs 2933 MT/s DR] |
|
Intel Optane PMem [1:4 DRAM: PMem ratio] |
- 1.5 TB [12 x 128 GB] + 384 GB DRAM (cache) - 3 TB [12 x 256 GB] + 768 GB DRAM (cache) |
FW: 01.02.00.5395 |
RAID controller |
PERC H740P Adapter |
FW: 50.9.2-2938 |
Local disks |
||
Operating system |
2 x 1.2 TB TOSHIBA 10K RPM SAS 12Gbps 512n 2.5” HDDs [1 x RAID1 Virtual Disk (VD)] |
FW: EF05 |
1 TB TPC-H-like schema (DATA) |
8 x 960 GB TOSHIBA SAS SSDs Mixed Use 12Gbps 512e 2.5” PM5-V drive, 3 DWPE, 5256 TBW [4 x RAID1 VDs] |
FW: B01C |
3 TB TPC-H-like schema (DATA) |
12 x 960 GB TOSHIBA SAS SSDs Mixed Use 12Gbps 512e 2.5” PM5-V drive, 3 DWPE, 5256 TBW [6 x RAID1 VDs] |
FW: B01C |
REDO 1 and REDO 2 |
4 x 1.92 TB TOSHIBA SAS-SSDs Mixed Use 12Gbps 512e 2.5” PM5-V drive, 3 DWPD, 10512 TBW [2 x RAID1 VDs] |
FW: B01C |
NVMe PCIe SSDs [IMFS disk area] |
4 x 3.2 TB, Intel NVMe, Mixed Use, 2.5” SFF drives, U.2, P4610 |
FW: VDV1DP21 |