The following table shows connections from each server to the switch ports with a 100 GbE NIC in PCI slot 2.
Table 2. Server-to-switch port connections
Role |
S5232F-1 |
S5232F-2 |
S3048 |
iDRAC IP VLAN 34 100.82.34.0/24 |
Public IP VLAN 461 100.82.46.0/26 |
csah |
1/1/1 |
1/1/1 |
1/1/1 |
100.82.34.20 |
100.82.46.20 |
etcd-0 |
1/1/2 |
1/1/2 |
1/1/2 |
100.82.34.21 |
100.82.46.21 |
etcd-1 |
1/1/3 |
1/1/3 |
1/1/3 |
100.82.34.22 |
100.82.46.22 |
etcd-2 |
1/1/4 |
1/1/4 |
1/1/4 |
100.82.34.23 |
100.82.46.23 |
worker1 |
1/1/5 |
1/1/5 |
1/1/5 |
100.82.34.24 |
100.82.46.24 |
worker2 |
1/1/6 |
1/1/6 |
1/1/6 |
100.82.34.25 |
100.82.46.25 |
bootstrap/worker3 |
1/1/7 |
1/1/7 |
1/1/7 |
100.82.34.26 |
100.82.46.26 |
The following table shows the firmware versions running in each switch model:
Table 3. Switch firmware version and default credentials
PowerSwitch model |
Out-of-band management IP |
Firmware version |
Default username |
Default password |
S5232F-1 |
100.82.33.44 |
10.5.1.0 |
admin |
admin |
S5232F-2 |
100.82.33.45 |
10.5.1.0 |
admin |
admin |
S3048 |
100.82.33.46 |
10.5.1.0 |
admin |
admin |
To modify the switches for your environment:
git clone https://github.com/dell-esg/openshift-bare-metal.git
The deployment uses untagged VLANs that use switchport access for nodes and tagged port channels for switch uplinks.
The deployment sample uses:
Note: The serial-port baud rate is 115200.
Note: Ethernet ports ens2f0 and ens2f1 in R640 servers are used in the rest of the document for CoreOS, p2p1, and p2p2 for Red Hat Enterprise Linux 7.x.