VCF requires the following additional VLANs created and configured on the TOR switches connecting to VxRail nodes in the management WLD VxRail cluster.
Note: From VCF 4.3, the edge cluster for the management workload domain is deployed as a Day-2 operation from the SDDC Manager. It is no longer deployed by cloud builder during the initial management workload domain deployment.
Table 4. VCF VLANs for management WLD deployment
Workload Domain | Network Traffic | Sample VLAN |
Management WLD | NSX-T Host TEP | 103 |
Management WLD | NSX-T Edge TEP | 104 |
Management WLD | Edge Uplink01 | 105 |
Management WLD | Edge Uplink02 | 106 |
Figure 12. VxRail Management WLD VxRail cluster VLANs (Uplink and Edge with AVN enabled)
VCF requires the following additional VLANs created and configured on the TOR switches before deploying a VI WLD.
Table 5. VCF VLANs for VI WLD deployment
Workload Domain Type | Network Traffic | Sample VLAN |
VI WLD | NSX-T Host TEP | 203 |
VI WLD (edge deployment only) | NSX-T Edge TEP | 204 |
VI WLD (edge deployment only) | Edge Uplink01 | 205 |
VI WLD (edge deployment only) | Edge Uplink02 | 206 |
Note: The Edge deployment is a Day 2 operation that can be achieved using either the Edge automation or a manual deployment after the VI WLD has been deployed.