Home > Workload Solutions > Container Platforms > Red Hat OpenShift Container Platform > Guides > Implementation Guide—Red Hat OpenShift Container Platform 4.14 on AMD-powered Dell Infrastructure > Introduction
Dell Technologies has provided sample switch configuration files to help you easily adapt and configure the switches that you use for the OpenShift Container Platform cluster.
git clone https://github.com/dell-esg/openshift-bare-metal.git
Note: If you use different hardware or require different configurations, modify the configuration files correspondingly. The configurations that are described in this section are provided for guidance on how to set up the network.
Dell PowerSwitch S5232F switches are in Virtual Link Trunking (VLT) mode and are uplinked to core switches in the environment. The PowerSwitch S3148 switch has an uplink to S5232F switches. The following table shows the port connections between the switches.
Note: The connections that are shown in the table are reflected in the sample switch configuration files.
Switch name | Port | Link description | S5232F-1 | S5232F-2 | S3148 |
S5232F-1 | 1/1/30 | Uplink to core switch | X | X | X |
S5232F-1 | 1/1/31 | VLTi | X | 1/1/31 | X |
S5232F-1 | 1/1/32 | VLTi | X | 1/1/32 | X |
S5232F-1 | 1/1/34 | Uplink to S3148 | X | X | 1/1/49 |
S5232F-2 | 1/1/30 | Uplink to core switch | X | X | X |
S5232F-2 | 1/1/34 | Uplink to S3148 | X | X | 1/1/50 |
S3148 | 1/1/4 | Dell Connectrix FC switch | X | X | X |