Use the VLANs from the pre-installation planning table "SDS networks" to create the VLANs on the MC node's ToR switches.
Sample configuration - VLANs
Complete the following tasks:- Change VLAN ID and description as required.
- Ensure that the MTU is set correctly.
- Complete on both ToR switches.
#SDS-1 VLAN
interface vlan1001
description SDS-1
no shutdown
mtu 9216
#SDS-2 VLAN
interface vlan1002
description SDS-2
no shutdown
mtu 9216
Sample configuration - Switchports
Next, configure the switchports connected to the ports on the dedicated NICs (NIC-6 in our example), reserved for this deployment.
- Change interface, description, and VLANs as required.
- Ensure that the MTU is set correctly.
- Complete for all MC Nodes.
interface ethernetx/x/xx
description MC-Node01_SDS
no shutdown
switchport mode trunk
switchport trunk allowed vlan 1001-1002
mtu 9216
flowcontrol receive off
vlt delay-restore orphan-port enable
spanning-tree bpduguard enable
spanning-tree port type edge