The number of cables that are needed for a cluster are summarized in:
Table 7. Per-rack network equipment Total racks | One (12 nodes nominal) |
Management switch | One PowerSwitch S3100-ON family |
Switch interconnect cable | One 1 GbE cable (to the next rack management switch) |
Table 8. Per-pod network equipment Total racks | Three (36 nodes) |
ToR pod switches | Two PowerSwitch S5248F-ON |
Pod uplink cables | Four 100 Gb QSFP+ cables (to the aggregate switch) |
ToR VLT cables | Two 25 Gb SFP28 cables |
Table 9. Per-cluster aggregation network switches for multiple pods Total Pods | Eight |
Aggregation layer switches | Two PowerSwitch Z9432F-ON |
See the PowerSwitch Z9432F-ON Spec Sheet for more information about the Z9432F-ON.
The required cluster networking equipment is summarized in Table 10.
Table 10. Per-node network cables required Master nodes | One per node | Two per node |
Edge nodes | One per node | Four per node |
Worker nodes | One per node | Two per node |
Note: 25 GbE node connections typically use a QSFP28 (100 Gbps) to SFP28 (25 Gbps) breakout cable. The cable count is typically one-fourth the number of connections in
Table 10.