Home > Storage > PowerFlex > White Papers > Snapshots Container Storage Modules (CSM) for Dell PowerFlex > Network architecture
The following diagram shows the network architecture of this solution:
Figure 5. Network design of OpenShift nodes and PowerFlex SO nodes
At the physical layer, two supported Top of Rack (TOR) switches are used for redundancy and load-balancing purposes. A peer link is configured on both the TOR switches. VLANs are created to separate different traffic types on the network bonds. The following table shows the different networks that are configured for this solution. See PowerFlex node VLAN setup for more information:
Table 2. Network details
Network type | VLAN ID |
Ingress/API | 105* |
Operating System Installation | 104 |
Hardware Management | 101 |
PowerFlex Management | 150 |
PowerFlex Data 1 | 151 |
PowerFlex Data 2 | 152 |
Note: 105*, is the network that is required for OpenShift Ingress/API and could connect to Internet using this VLAN.
For more information about OpenShift networking, see Configuring and managing cluster networking.