The following table summarizes the host connectivity limits for PowerMaxOS iSCSI:
Component |
Maximum values |
|||
Per SE port |
Per SE instance |
Per director |
Per engine |
|
VLANs |
64 |
512 |
512 |
1024 |
SE Instance |
NA |
NA |
1 |
2 |
Physical SE Ports |
NA |
16 |
16 |
32(1) |
Network IDs |
NA |
512 |
512 |
1024 |
Routing Instances |
NA |
1024 |
1024 |
2048 |
IP Interfaces |
64 |
512 |
512 |
1024 |
iSCSI Targets |
64 |
512 |
512 |
1024 |
Host Connections |
2048 |
8192 |
8192(2) |
16384 |
(1) Maximums of 32 SE ports on the VMAX 250F and PowerMax 2000 and 24 ports on the VMAX 950F and PowerMax 8000
(2) The director host connection limit is a total that includes hosts using other front-end instances (Fibre Channel) that could be configured on the director.