Home > Workload Solutions > Container Platforms > Red Hat OpenShift Container Platform > Archive > Implementation Guide—Red Hat OpenShift Container Platform 4.10 on Intel-powered Dell Infrastructure > PowerStore CSI driver topologyUsing CSI drivers to configure storage
OpenShift Container Platform cluster administrators can map storage to containers. For a list of supported Persistent Volume (PV) plug-ins, see Types of PVs in the OpenShift Container Platform documentation.
Note: The solution has been validated with PowerMax, PowerScale, and PowerStore storage systems.
This chapter includes the following topics:
To configure multipath across compute nodes:
[core@csah-pri multipathd]$ echo 'defaults {
user_friendly_names yes
find_multipaths yes
}
blacklist {
}' | base64 -w0
[core@csah-pri multipathd]$ oc create -f <machine config YAML>
Note: This machine configuration applies only to compute nodes. After the machine configuration file is created and applied, each compute node is rebooted one at a time.
The CSI operator for OpenShift is available on the Red Hat OpenShift embedded operator hub.
To install the CSI operator:
[core@csah-pri ~]$ oc get pods -n <namespace>
NAME READY STATUS RESTARTS AGE
dell-csi-operator-controller-manager-55b9b99856-84sqk 1/1 Running 0 39s