Home > Workload Solutions > Container Platforms > Red Hat OpenShift Container Platform > Archive > Design Guide—Red Hat OpenShift Container Platform 4.10 on Intel-powered Dell Infrastructure > Dell PowerEdge R750 BOM
The following table shows the PowerEdge R750 baseline configurations that are used in this design for OpenShift Container Platform 4.10:
Quantity | SKU | Description |
1 | [210-AYCG] | PowerEdge R750 server |
1 | [379-BDTF] | Chassis with up to 24 x 2.5” drives |
1 | [379-BDSW] | SAS/SATA/NVMe capable backplane |
1 | [321-BGZG] | 2.5" chassis with up to 24 drives (16 SAS/SATA + 8 NVMe Direct), 2 CPU |
1 | [338-CBCJ] | Intel® Xeon® Gold 6338 2G, 32C/64T, 11.2GT/s, 48M Cache, Turbo, HT (205W) DDR4-3200 |
1 | [338-CBCJ], [379-BDCO] | Intel® Xeon® Gold 6338 2G, 32C/64T, 11.2GT/s, 48M Cache, Turbo, HT (205W) DDR4-3200 |
1 | [412-AAVB] | Heatsink for 2 CPU configuration (CPU greater than or equal to 165W) |
1 | [370-AEVR] | 3200MT/s RDIMMs |
16 | [370-AGDS] | 32 GB RDIMM, 3200MT/s, Dual Rank, 16 Gb BASE x8 |
1 | [405-AAZB], [750-ACFQ] | Front PERC H755 Rear Load |
12 | [400-AZQO] | 800 GB SSD SAS ISE Mix Use 12 Gbps 512e 2.5” Hot-plug AG Drive, 3 DWPD, |
4 | [400-BKGF] | 1.6 TB Enterprise NVMe Mixed Use AG Drive U.2 Gen4 with carrier |
1 | [450-AJEV] | Dual, Hot-Plug, Power Supply Fault Tolerant Redundant (1+1), 2400W, Mixed Mode |
1 | [528-CRVW], [528-CTZH] | iDRAC9 Datacenter 15G with OpenManage Enterprise Advance Plus |
1 | [540-BCOF] | Mellanox ConnectX-5 Dual Port 10/25 GbE SFP28, OCP NIC 3.0 |
1 | [540-BCMQ] | Mellanox ConnectX-5 Dual Port 10/25 GbE SFP28 Adapter, PCIe Low Profile |
1 | [406-BBMP] | Emulex LPE 35002 Dual Port 32 Gb Fibre Channel HBA, PCIe Full Height |
1 | [403-BCLZ], [470-AERR] | BOSS-S2 controller card+ with 2 M.2 480 GB (No RAID) |