Home > Workload Solutions > Container Platforms > Red Hat OpenShift Container Platform > Archive > Deployment Guide--Dell Ready Stack for Red Hat OpenShift Container Platform 4.3 CSI Attached Storage > PowerMax iSCSI driver configuration file
Use the following sample configuration file to create the CSI PowerMax iSCSI driver. For information about environment variables, see Dell CSI Operator - PowerMax Environment Variables.
'''
- Ensure namespace (powermax) is specified appropriately.
- X_CSI_POWERMAX_ENDPOINT - management IP of PowerMax is specified
- X_CSI_K8S_CLUSTER_PREFIX value is added for every host and volume created using CSI drivers
- X_CSI_POWERMAX_PORTGROUPS value is obtained from Unisphere for PowerMax -> HOSTS -> Port Groups
- SRP info is listed under Unisphere IP of PowerMax -> STORAGE -> Storage Resource Pools
- SYMID is listed under "All Systems" in Unishpere for PowerMax -> Home Page
'''
apiVersion: storage.dell.com/v1
kind: CSIPowerMax
metadata:
name: test-powermax
namespace: powermax
spec:
driver:
common:
envs:
- name: X_CSI_POWERMAX_ENDPOINT
value: 'https://100.82.47.42:8443'
- name: X_CSI_K8S_CLUSTER_PREFIX
value: OS4
- name: X_CSI_POWERMAX_PORTGROUPS
value: 'SEPort'
- name: X_CSI_TRANSPORT_PROTOCOL
value: 'iSCSI'
image: 'dellemc/csi-powermax:v1.3.0.000R'
imagePullPolicy: IfNotPresent
configVersion: v2
forceUpdate: false
replicas: 1
storageClass:
- name: iscsi
parameters:
SRP: SRP_1
SYMID: '000197900896'
ServiceLevel: Bronze
reclaimPolicy: Delete