This section describes Dell EMC Networking OS10 initial OOB management IP setup and provides sample switch configuration directions copied to running-configuration.
Follow these steps:
The following code sample shows an S5232F-1 switch. The same process applies for S5232F-2 and S3048 switches.
OS# configure terminal
OS(config)# hostname S5232F-1
S5232F-1(config)# interface mgmt 1/1/1
S5232F-1(conf-if-ma-1/1/1)# no shutdown
S5232F-1(conf-if-ma-1/1/1)# no ip address dhcp
S5232F-1(conf-if-ma-1/1/1)# ip address 100.82.33.44/24
S5232F-1(conf-if-ma-1/1/1)# exit
S5232F-1(config)# management route 0.0.0.0/0 100.82.33.1
S5232F-1# copy scp://<user>@<hostip>/<path to downloaded S5232F config file> running-configuration
S5232F-1# write memory