Steps to install the SDC driver which is configured on all the KVM hypervisor hosts.
1. Before proceeding with the SDC installation, ensure that the PowerFlex data networks (PowerFlex data1 and data2) have been configured on the KVM hosts.
2. Run the following command to copy the PowerFlex SDC packages onto KVM hosts and install them:
# MDM_IP=<LIST_VIP_MDM_IPS> rpm -i <SDC_PATH>.rpm
where
<LIST_VIP_MDM_IPS> is a comma-separated list of all the MDM IP addresses or the virtual IP address of the MDM. Do not include tiebreaker addresses here.
<SDC_PATH> is the path where the SDC installation package is located.
3. Reboot the host.
4. Verify that the driver is loaded by running the following command:
# service scini status
5. Repeat steps 1 to 4 for all the KVM hosts.
6. Log in to the PowerFlex Manager GUI. Navigate to Block > Hosts and verify that the KVM hosts are listed as shown in the following figure:
Figure 9. SDC Host lists